Section 7 Refrigeration System
7-3
REMOTE MODELS
Remote Pre-Chill and Freeze Cycle (Models J450/J600/J800/J1000)
Prechill Refrigeration Sequence
No water flows over the evaporator during the
prechill. The refrigerant absorbs heat (picked up
during the harvest cycle) from the evaporators. The
suction pressure decreases during the prechill.
Freeze Cycle Refrigeration Sequence
The refrigerant absorbs heat from the water running
over the evaporator surface. The suction pressure
gradually drops as ice forms.
The headmaster control valve maintains discharge
pressure in cold ambient temperatures. (See
“Headmaster Control Valve” on page 7-28.)