EasyManuals Logo
Home>Manitowoc>Ice Maker>J250

Manitowoc J250 User Manual

Manitowoc J250
165 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #145 background imageLoading...
Page #145 background image
Section 7Refrigeration System
7-40
J1300 SERIES
SELF-CONTAINED AIR-COOLED
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Cycle Time
Air Temp. Freeze Time Harvest
Entering
Condenser
Water Temperature °
°°
°F/°
°°
°C
Time
°
°°
°F/°
°°
°C 50/10.0 70/21.1 90/32.2
70/21.1
8.8-9.8 10.2-11.4 11.5-12.8
80/26.7
9.1-10.1 10.5-11.7 12.0-13.3
1-2.5
90/32.2
9.8-10.9 11.4-12.6 13.0-14.5
100/37.8
10.8-12.0 12.8-14.2 14.9-16.5
1
Times in minutes
24 Hour Ice Production
Air Temp.
Entering
Water Temperature °
°°
°F/°
°°
°C
Condenser
°
°°
°F/°
°°
°C
50/10.0 70/21.1 90/32.2
70/21.1
1400 1230 1110
80/26.7
1360 1200 1070
90/32.2
1280 1120 990
100/37.8
1170 1010 880
1
Based on average ice slab weight of 10.0 - 11.0 lb.
2
Regular cube derate is 7%
Operating Pressures
Air Temp. Freeze Cycle Harvest Cycle
Entering
Condenser
°
°°
°F/°
°°
°C
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
50/10.0
220-280 40-20 140-170 65-80
70/21.1
220-280 40-20 145-170 70-80
80/26.7
220-280 42-22 150-185 70-80
90/32.2
245-300 48-26 160-190 70-85
100/37.8
275-330 50-26 160-210 70-90
110/43.3
280-360 52-28 165-225 75-100
1
Suction pressure drops gradually throughout the freeze cycle
J1300 SERIES WATER-COOLED
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Cycle Time
Air Temp. Freeze Time Harvest
Around Ice
Machine
Water Temperature °
°°
°F/°
°°
°C
Time
°
°°
°F/°
°°
°C 50/10.0 70/21.1 90/32.2
70/21.1
8.5-9.5 9.5-10.6 11.1-12.4
80/26.7
8.6-9.7 9.7-10.8 11.4-12.6
1-2.5
90/32.2
8.8-9.8 9.8-11.0 11.6-12.9
100/37.8
8.9-10.0 10.0-11.2 11.8-13.2
1
Times in minutes
24 Hour Ice Production
Air Temp.
Around Ice
Water Temperature °
°°
°F/°
°°
°C
Machine
°
°°
°F/°
°°
°C
50/10.0 70/21.1 90/32.2
70/21.1
1440 1310 1140
80/26.7
1420 1290 1120
90/32.2
1400 1270 1100
100/37.8
1380 1250 1080
1
Based on average ice slab weight of 10.0 - 11.0 lb.
2
Regular cube derate is 7%
Condenser 90/32.2 Air Temperature Around Ice Machine
Water Water Temperature °
°°
°F/°
°°
°C
Consumption 50/10.0 70/21.1 90/32.2
Gal/24 hours
1150 2400 7700
1
Water regulating valve set to maintain 240 PSIG discharge
pressure
Operating Pressures
Air Temp. Freeze Cycle Harvest Cycle
Around Ice
Machine
°
°°
°F/°
°°
°C
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
50/10.0
235-245 40-18 150-180 70-80
70/21.1
235-245 40-18 150-180 70-80
80/26.7
235-245 40-20 150-180 70-80
90/32.2
235-250 42-20 150-180 70-80
100/37.8
235-255 44-20 150-180 70-80
110/43.3
240-265 46-20 150-180 70-80
1
Suction pressure drops gradually throughout the freeze cycle

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc J250 and is the answer not in the manual?

Manitowoc J250 Specifications

General IconGeneral
BrandManitowoc
ModelJ250
CategoryIce Maker
LanguageEnglish

Related product manuals