Section 6 Electrical System
6-47
ELECTRONIC CONTROL BOARD (NEW STYLE)
New Style Control Board
New Style Control Board Improvements
• A dual voltage transformer means only one
control board for both 115V and 208-230V use.
• One 7-amp fuse - no separate transformer fuse.
• A single ice thickness probe provides improved
ice thickness control by eliminating the possibility
of scale or slime bridging the probes, causing
premature harvests.
• A yellow “Clean” light energizes when a SeCS
or AuCS cycle is in progress.
CAUTION
J model control boards that have only terminal 1C
(no terminal 1D on board), must use the new single
probe ice thickness control
• An adjustable harvest cycle water purge can be
set to 15, 30 or 45 seconds. This will not affect
clean cycle purge time.
CAUTION
This control is factory-set to 45 seconds. A reduced
setting will increase cleaning frequency.
• Safety limits 3 and 4 have been eliminated; no
thermistor is required.
• Exact control board replacement when replacing
an old style control board with a new style control
board. Electrical sequence of operation is
identical to the old style control board.
57
58
60
61
MAIN FUSE (7A)
AUTOMATIC CLEANING SYSTEM
(AuCS)
ACCESSORY PLUG
ICE THICKNESS PROBE
(3/16” CONNECTION)
NOT USED
DC LOW VOLTAGE
ELECTRICAL PLUG
NUMBERS MARKED ON WIRES
HARVEST LIGHT/
SAFETY LIMIT CODE LIGHT -- RED
BIN SWITCH LIGHT -- GREEN
AC LINE VOLTAGE
ELECTRICAL PLUG
NUMBERS MARKED ON WIRES
N 115V
L
2
208-230V
L
1
PRIMARY
POWER SUPPLY
55
LIGHT NOT USED -- GREEN
CLEAN LIGHT -- YELLOW
WATER PURGE ADJUSTMENT
SV1588
56
1C
1F
68
67
62
65
63