Section 7Refrigeration System
7-56
REFRIGERANT RE-USE POLICY
Manitowoc recognizes and supports the need for
proper handling, re-use, and disposal of, CFC and
HCFC refrigerants. Manitowoc service procedures
require recapturing refrigerants, not venting them to
the atmosphere.
It is not necessary, in or out of warranty, to reduce or
compromise the quality and reliability of your
customers’ products to achieve this.
Important
Manitowoc Ice, Inc. assumes no responsibility for
use of contaminated refrigerant. Damage resulting
from the use of contaminated, recovered, or
recycled refrigerant is the sole responsibility of the
servicing company.
Manitowoc approves the use of:
New Refrigerant
Must be of original nameplate type.
Reclaimed Refrigerant
Must be of original nameplate type.
Must meet ARI Standard 700 (latest edition)
specifications.
Recovered or Recycled Refrigerant
Must be recovered or recycled in accordance
with current local, state and federal laws.
Must be recovered from and re-used in the
same Manitowoc product. Re-use of
recovered or recycled refrigerant from other
products is not approved.
Recycling equipment must be certified to ARI
Standard 740 (latest edition) and be
maintained to consistently meet this standard.
Recovered refrigerant must come from a
“contaminant-free” system. To decide
whether the system is contaminant free,
consider:
Type(s) of previous failure(s)
Whether the system was cleaned,
evacuated and recharged properly
following failure(s)
Whether the system has been
contaminated by this failure
Compressor motor burnouts and improper
past service prevent refrigerant re-use.
Refer to “System Contamination Cleanup”
to test for contamination.
“Substitute” or “Alternative” Refrigerant
Must use only Manitowoc-approved
alternative refrigerants.
Must follow Manitowoc-published conversion
procedures.