52 Part Number STH042 3/14
SAFETY LIMITS
Safety limits are stored and indicated by the control
board. The number of cycles required to stop the ice
machine varies for each safety limit.
Safety limits can be reset by pressing the On/Off
button and starting a new ice making cycle.
A safety limit is indicated by a flashing Service Light on
the touch pad.
Safety Limit 1
If the freeze time reaches 60 minutes, the control
board automatically initiates a harvest cycle.
After 3 consecutive 60 minute cycles control board
light SL#1 along with the touch pad service
(wrench) light will flash on/off at 1 second intervals.
If 6 consecutive 60-minute freeze cycles occur, the
ice machine stops and the SL#1 light on the
control board and the service (wrench) light on the
touch pad will be on continuously.
Safety Limit 2
If the harvest time reaches 3.5 minutes, the control
board automatically returns the ice machine to the
freeze cycle.
If three consecutive 3.5 minute harvest cycles
occur the SL#2 light on the control board will flash
on/off at 1 second intervals.
If 75 consecutive 3.5 minute harvest cycles occur
the wrench light on the touch pad will flash on/off
at 1 second intervals.
If 100 consecutive 3.5 minute harvest cycles
occur, the ice machine stops and the SL#2 light on
the control board and the service (wrench) light on
the touch pad will be on continuously.