244 Part Number 80-1505-3 6/11
IB0682DC/CVD685 SERIES REMOTE AIR COOLED
NOTE: These characteristics may vary depending on
operating conditions.
CYCLE TIMES
24-HOUR ICE PRODUCTION
OPERATING PRESSURES
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10 70/21 90/32
-20 to 70/
-29 to 21
9.2-10.6 10.1-11.6 11.1-12.8
.75-2.5
90/32 9.5-11.0 10.5-12.1 11.6-13.3
100/38 10.2-11.8 11.4-13.0 12.6-14.4
110/43 11.2-12.9 12.6-14.4 14.1-16.1
1
Times in minutes.
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10 70/21 90/32
-20 to 70/
-29 to 21
620 570 525
90/32 600 550 505
100/38 565 515 470
110/43 520 470 425
1
Based on average ice slab weight of 4.6-5.2 lb.
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle Harvest Cycle
Discharge
Pressure
psig
Suction
Pressure
psig
Discharge
Pressure
psig
Suction
Pressure
psig
-20 to 50/
-29 to 10
215-260 46-26 140-185 70-95
70/21 220-270 51-26 150-190 70-100
80/27 225-285 56-27 155-195 80-105
90/32 235-295 59-28 165-200 85-105
100/38 260-340 60-30 180-210 85-112
110/43 300-385 65-34 195-230 90-120