–96–
UG030A-161 SELF-CONTAINED AIR-COOLED — STANDARD CUBE (Continued)
Operating Pressures
Air Temp. Entering
Condenser °C
Freeze Cycle Harvest Cycle
Discharge Pressure Suction Pressure Discharge Pressure
Suction Pressure
All pressures are in bar. Suction pressure drops gradually throughout the freeze cycle.
10 5.11-3.20 0.55-0.22 5.00-9.88 1.10-2.96
21 7.88-5.81 0.58-0.39 5.50-9.30 1.38-2.98
32 9.90-6.91 2.30-0.82 6.78-12.48 2.99-3.20
43 14.18-10.21 2.47-0.89 8.53-17.59 3.00-3.40