–117–
UG080A SELF-CONTAINED AIR-COOLED — STANDARD CUBE (Continued)
Operating Pressures
-
Air Temp. Entering
Condenser °C
Freeze Cycle Harvest Cycle
Discharge Pressure Suction Pressure Discharge Pressure
Suction Pressure
All pressures are in bar. Suction pressure drops gradually throughout the freeze cycle.
*: peak fan motor shut down.
10 13.42-28.07* 4.75-3.50 12.60-13.90 8.70-10.40
21 16.60-13.85 4.91-3.50 12.65-13.90 8.70-10.45
32 21.00-17.90 5.38-3.70 12.80-14.01 8.75-10.47
43 25.83-24.30 25.20-4.20 14.25-15.82 9.85-11.74