25
I
ICE CUBE THICKNESS CHECK
The ice cube thickness is factory-set to maintain the
ice cube thickness at the proper size and weight.
1. Allow the ice machine to operate for three
complete cycles. The cubes should have a small
dimple in the center.
2. Cycle times vary, according to surrounding air and
water inlet temperatures.
3. If cubes are not full (large dimple), raise the “dip
switch” level to increase cube size. Allow ice
machine to complete three cycles, then check
cube.
4. If cubes are too full, ( no dimple), lower the “dip
switch” level to decrease cube size.Allow ice
machine to operate three complete cycles.
5. The “dip switch” can be adjusted to five levels: -2/
-1/0/
+
1/
+
2, and ensure that only one level switch
is pressed