–114–
UG065 SELF-CONTAINED AIR-COOLED — STANDARD CUBE (Continued)
Operating Pressures
Air Temp. Entering
Condenser °C
Freeze Cycle Harvest Cycle
Discharge Pressure Suction Pressure Discharge Pressure
Suction Pressure
All pressures are in bar. Suction pressure drops gradually throughout the freeze cycle.
*: peak fan motor shut down.
10 8.68-20.50* 11.23-14.60 6.37-8.40
21 13.50-12.66 1.88-1.40 11.25-14.65 6.40-8.51
32 19.04-17.06 2.43-1.85 11.33-16.65 6.53-10.02
43 25.01-22.24 3.15-2.65 13.34-19.87 8.02-12.20