19
Step 8 After 13.5 minutes, set the toggle switch to the
OFF position. Remove water curtain, ice chute and
over flow tube from the water sump. Allow all water to
drain from the sump. Replace drain plug . Set toggle
switch to WASH and circulate for 12minutes.
Step 9 Wait until the cleaning cycle(12
minutes) is
complete then place the toggle switch in the OFF
position.Remove water curtain, ice chute, water sump
over flow tube. Drain water from sump and replace
tube.
Step 10 Mix 60 ml of sanitizer with 12 l of water in a
plastic or stainless steel container.
Step 11 Remove Water Curtain and Ice Chute as
described in Section 3, Component Identification &
Removal.
Step 12 Take all components to sink and with 10 liters
Sanitizer/Water mixture sanitize all components with a
soft nylon brush or cloth. Do not rinse components.
Step 13 Use brush or cloth to sanitize the inside of ice
bin. Scrub inside of door, door track, bin, water sump,
water distribution assembly and evaporator moldings.
Do not rinse.
Step 14 Replace sump drain over flow tube, and
transfer remaining 2 liters of solution to the sump
trough. Replace all components.
Step 15 To start a sanitizing cycle, set the toggle
switch to the WASH position.
Step 16 After 13.5 minutes, set the toggle switch to
the OFF position. Remove water curtain and ice chute
Remove over flow tube from water sump and allow all
water to drain from sump. Replace drain plug. Set
toggle switch to WASH and circulate for 12
minutes.
Step 17 Wait until the cleaning cycle (12
minutes) is
complete then place the toggle switch in the OFF
Sanitizer Water
60 ml (2 oz) 12 l (3 gal)