11 12
3.2.3 DC Current
Accuracy
Resolution
Measuring range
±(2.5% reading + 8 digits)
60A
600A
1000A
0.01A
0.1A
1A
- Maximum input current: 1000A DC
3.2.4 Surge Current
Accuracy
Resolution
Measuring range
60A
600A
1000A
0.01A
0.1A
1A
< 60A for reference only
±(10% reading + 60 digits)
Time of integration: 100ms; measurement range:
10~1000A; frequency range: 40~400Hz
3.2.5 DC Voltage
Accuracy
Resolution
Measuring range
±(0.8% reading + 4 digits)
1V
±(0.5% reading + 5 digits)
0.1V
0.01V
0.001V
0.1mV600mV
6V
60V
600V
1000V
- Input impedance: 10MΩ
- Maximum input voltage: 750V AC (RMS) or 1000V DC
- 600mV measuring range can be inputted only by
RANGE key.
Note:
In the small voltage measuring range, the probe is not
connected with the circuit to be tested, and the meter
may have fluctuating readings, This is normal and
caused by the meter's high sensitivity, and does not
affect actual measurement results.
3.2.6 AC Voltage
Accuracy
Resolution
Measuring range
±(0.8% reading + 4 digits)
1V
±(0.8% reading + 5 digits)
0.1V
0.01V
0.001V
0.1mV600mV
6V
60V
600V
750V
- Input impedance: 10MΩ
- Maximum input voltage: 750V AC (RMS) or 1000V DC
- Frequency range: 50 ~ 60Hz
- 600mV measuring range can be inputted only by
RANGE key.
Note:
In the small voltage measuring range, the probe is not
connected with the circuit to be tested, and the meter
may have fluctuating readings, This is normal and
caused by the meter's high sensitivity. This does not
affect the actual measurement results.