36
CHAPTER 8: TROUBLESHOOTING
8.2 ERROR CODE LIST
CODE CLASS DESCRIPTION MACHINE SOLUTION
01A1 C Incline calibration error A
a.
It occurs when the calibration time is too long or the calibration distance is too
short.
b. Don’t fix the incline motor tube then turn on the power.
-
If the console still shows 01A1, please replace incline motor
.
- If auto calibration is finished, please follow the incline motor installation
SOP to fix incline motor.
c.
Replace LCB.
01A3 C Motor is disconnected T
a.
Check the connection of the motor cable at the MCB.
b. Check if the MCB LED DSP1 (MCU).
-
If LED DSP1 is blinking or solid light, replace the motor
-
If LED DSP1 is not lit, replace the MCB.
01A8 C Main motor over current T
a.
Check the condition of the running deck and belt. Replace the belt and flip or
replace the running deck as needed.
b.
Replace the MCB.
01AC C
Electro magnet (ECB) over
current
HUR
a.
Check if the Electro-magnet is short circuited or open.
b. If the resistance data shows a short/open ohms or is outside the range of 12.8
~14.2 ohms, replace the Electro-magnet.
c. If the resistance data is in the range between 12.8 ~14.2 ohms, replace the LCB.
C
a.
On standby mode, measure the resistance on ECB1 and ECB2. Please check the
ECB extension cable connection at the LCB (pins 1 & 3 for ECB1, pins 2 & 4 for
ECB2), there should be between 12.8 ~ 14.2 ohms.
- If the ECB resistance is out of the range, replace the ECB.
-
If the ECB resistance is within the range, replace the LCB.
b.
Check the gap of ECB1 and ECB2. There should be a gap of .5mm between the
ECB and the flywheel.
01AF C
Electro magnet (ECB) dis
-
connected
HUR
a.
Check if the Electro-magnet is short circuited or open.
b. If the resistance data shows a short/open ohms or is outside the range of 12.8
~14.2 ohms, replace the Electro-magnet.
c. If the resistance data is in the range between 12.8 ~14.2 ohms, replace the LCB.
Resistance disconnect A
a.
Check if the resistance is short circuit.
-
If resistance data is under 10 ohms, please replace power resistance.
-
If resistance data is over 10 ohms, please replace LCB.
Electro magnet (ECB) dis-
connected
C
a.
Check the connection of the ECB extension cable from the LCB to the ECB.
b.
Check to see if LED8 and LED10 on the LCB have a brief light for 3 second when
you power on machine.
-
If LED8 and LED10 do not have a brief light, replace the LCB.
-
If LED8 and LED10 do have a brief light, check the ECB
extension cable
connection at the LCB (pins 1 & 3 for ECB1, pins 2 & 4 for ECB2), there
should be between 12.8 ~ 14.2 ohms.
- If the ECB resistance is out of the range, replace the ECB.
c.
If the ECB resistance is within the range, replace the LCB.
01B4 C
Battery connection reverse
protection
AHUR
a.
Check the battery wire connection between the battery and LCB.
b. Check the battery voltage.
-
If there is no data on voltage, replace the battery
.
- If there is data on voltage, replace the LCB.
014A
(01AE)
B
LCB charge current is
abnormal
AHUR
a.
Replace LCB.
0140 B Incline motor operation fail A
a.
Please run
Auto Calibration.
b. If the error code happens in Auto-calibration, the machine still can work, no need
to do anything.
c. If the error code happens in workout, please replace the incline motor
.
0141 B Motor over temperature T
a.
Check the connection of the motor cable at the MCB.
b. Use a multi-meter to check the motor wire circuit. Set the multi-meter to Ohms
and place both terminals on the blue wires of the motor cable.
-
If there is an Ohm reading above 0, replace the motor
.
-
If the Ohm reading is 0, replace the MCB.
0144 B Motor over current T
a.
Check the condition of the running deck and belt. Replace the belt and flip or
replace the running deck as needed.
b. Replace the MCB.