CHAPTER 8: TROUBLESHOOTING
8.2 ERROR CODE LIST - CONTINUED
CODE CLASS DESCRIPTION MACHINE SOLUTION
0440 B Timeout receive packet.
Communication
Errors
a.
Enter the Engineer mode disable B Level Error, by pass CLASS
A
and B error code.
b.
Check the connection of the console cable at both ends and per-
form continuity test.
c.
Replace LCB.
0441 B
When UCB implements a
command, LCB has no this
command
Communication
Errors
a.
Enter the Engineer mode disable B Level Error
, by pass CLASS
A
and B error code.
0442 B
The received command code
from the console is correct
and is supported, but it has
less or more data arguments
Communication
Errors
a. Enter the Engineer mode disable B Level Error, by pass CLASS
A
and B error code.