EasyManuals Logo
Home>Matrix>Fitness Equipment>A5X-04

Matrix A5X-04 User Manual

Matrix A5X-04
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
22
8.5 ERROR CODE TROUBLESHOOTING - 01A0
FIGURE A
CHAPTER 8: TROUBLESHOOTING
ERROR CODE 01A0
1) SYMPTOM:
a. 01A0 - Incline motor disconnected.
2) SOLUTION:
a. Check the Machine Type in Service Mode.
b. Check the connection of the incline motor at the LCB.
c. Run auto calibration (see Section 4.8).
d. If auto calibration fails, re-enter Engineering Mode and again go to Calibration.
- Measure the incline VR value (Figure A) by measuring across the Blue / Orange and Brown / Orange wiring in the incline motor wire
harness. The VR range should be 0.5k - 9.5k ohms (for example if the circuit is open or shorted). If the VR is outside of this range, replace the
incline motor.
e. If the incline motor does not resolve the issue, replace the LCB. NOTE: Run auto calibration if the incline motor or LCB is replaced.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Matrix A5X-04 and is the answer not in the manual?

Matrix A5X-04 Specifications

General IconGeneral
BrandMatrix
ModelA5X-04
CategoryFitness Equipment
LanguageEnglish

Related product manuals