4.8 AUTO CALIBRATION INSTRUCTIONS
CHAPTER 4: CONSOLE OVERLAY AND WORKOUT DESCRIPTION
AUTO CALIBRATION PROCEDURE
After initial installation or replacement of the incline motor, auto calibration should be run.
1) Press ENTER, 2, 0, 0, 1, ENTER on the keypad to go into Engineering Mode.
2) Press the key next to CALIBRATION on the display.
3) Press the key next to AUTO CALIBRATION on the display.
4) Press the key next to START on the display.
5) This will run the Auto Calibration. If the calibration passes, it will say complete. Press and hold the STOP key to return to the normal start
screen.
6) If the calibration does not pass, contact Matrix Customer Technical Support at 866-693-4863 ext 3.