8.12 TROUBLESHOOTING - NO POWER TO THE CONSOLE
NO POWER TO THE CONSOLE
1) SYMPTOM:
a. The unit is not getting power from the outlet.
b. The LCB is not getting power from the power receptacle.
c & d. The LCB LEDs are lit, but there is no power to the console.
2) SOLUTION:
a. Remove the front cover and check to see if LED D15 is lit on the LCB (Figure A). If it is not, verify power at the outlet. If the outlet is not
outputting 120V, check the fitness room power.
- If LED D15 is still not lit after checking fitness room power, replace the power cord.
b. Check if LED D15 on the LCB is lit. If it is not lit, check for incoming AC voltage at the LCB.
- Replace the power components as needed if voltage is not present.
- Replace the LCB if all power components are ok and there is AC voltage to the LCB.
c. Check to see if LED D18 is lit on the UCB (Figure B).
- If LED D18 is lit, check the switch on the back of the IO Board. It should be pointed towards the right side (Figure B).
- If LED D18 is not lit, check the console cable connection at the LCB and console. If this does not resolve the issue, replace the
console cable. If LED D18 is still not lit, replace the console.
FIGURE BFIGURE A
CHAPTER 8: TROUBLESHOOTING

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Matrix C7X - 03 and is the answer not in the manual?

Matrix C7X - 03 Specifications

General IconGeneral
BrandMatrix
ModelC7X - 03
CategoryFitness Equipment
LanguageEnglish

Related product manuals