MCQUAY Service Guide Book Handset Operating Guide
18
Differences between Netware 3 & Netware 3C:
Netware 3 Netware 3C
Compatibility
Non-inverter / X-inverter
Series
Y-inverter Series
Casing Color Dark Silver White
Retrieve Last State Error No Yes
Pump Down No Yes
Applicable model All except A(5)WM-J/JR
For MCK-E, only applicable
with nomenclature ACOBB
All except M5WMY-J/JR
NIM/G-WAY Yes
For MCK-E, only applicable
with nomenclature ACOBB
No
Operating Guide
1. “ON/OFF” Switch
• Caution: In the case when the ON/OFF
key is pressed immediately after the
operation is stopped, the unit will not
restart until 3 minutes later to protect the
compressor.
2. Selecting Operating Mode
• Press the MODE key to select the type of
operating mode. Consecutive press of the
key switches the
• operation over “COOL”, “HEAT”, “AUTO”,
“DRY” and “FAN”
3. Fan Speed Selection
• Press the FAN key until the desired fan
speed is achieved.
4. Sleep Mode Setting
• Press the SLEEP key to activate sleep
mode. Available under COOL, HEAT &
AUTO mode.
• When it is activated in COOL mode, the
set temperature will be increased 0.5°C
after 30mins, 1°C after 1 hour and 2°C
after 2 hours.
Jumper
20 - 30
Application
SET Set temp range : 20°C ~ 30°C
OFF Set temp range : 16°C ~ 30°C
1. Time display
2. Key lock display
3. Error indication
4. Fan speed display
5. Operation mode display
6. Sleep mode display
7. Air swing display
8. Temperature set display