MX 430B
32
NotaNota
NotaNota
Nota : if the pointer does not deflect :
1.5 and 15 A ranges : check 10 A fuse
other ranges
> 15 A check 0.16 A fuse
* Warning * Warning
* Warning * Warning
* Warning : 15 A AC measurement is limited to 5 minutes (10 A AC perma-
nent) only if the waveform has a perfect sine shape. If not the true
RMS, equivalent to the "mean value" of the rectified signal, could
overflow the RMS limit and thus could deliver an undesirable
overheating.
Recall :Recall :
Recall :Recall :
Recall : When measuring high current voltage for a long while, take out
the multimeter out of its rubber shock absorber or carrying case.
> 3 A use leads with convenient wires.
3.4 ACCESSORIES OPERATION3.4 ACCESSORIES OPERATION
3.4 ACCESSORIES OPERATION3.4 ACCESSORIES OPERATION
3.4 ACCESSORIES OPERATION
3.4.1 50 mV Shunts3.4.1 50 mV Shunts
3.4.1 50 mV Shunts3.4.1 50 mV Shunts
3.4.1 50 mV Shunts
Multimeter on
50 mV DC range
Unit/FactorUnit/Factor
Unit/FactorUnit/Factor
Unit/Factor
A : 1
A x 2
A x 10
Read on scaleRead on scale
Read on scaleRead on scale
Read on scale
50 black
50 black
50 black
50 mV Shunts50 mV Shunts
50 mV Shunts50 mV Shunts
50 mV Shunts
50 A
100 A
500 A