Product Features 6
heating mode:
T3 rises above TCDE1+4°C.
T3 maintained above TCDE2+4°C for 80 seconds.
Unit runs for 15 minutes consecutively in defrosting
mode.
3.4.5 Evaporator Temperature Protection
When the evaporator temperature exceeds a preset
protection value, the compressor ceases operations.
3.5 Auto-mode
This mode can be selected with the remote controller
and the temperature setting can be adjusted between
16°C~30°C.
In auto mode, the machine selects cooling, heating,
auto-drying or fan-only mode on the basis of T1,Ts, T4
and relative humidity.
If the setting temperature is modified, the machine
selects a new running function.
3.6 Drying mode
In drying mode, AC operates the same as auto fan in
cooling mode.
1) Mute function is active.
All protections are activated and operate the same as
they do that in cooling mode.
2) Low Room Temperature Protection
If the room temperature is lower than 10°C, the
compressor ceases operations and does not resume
until room temperature exceeds 12°C.
3.7 Forced operation function
Forced cooling mode:
The compressor and outdoor fan continue to run and
the indoor fan runs at rated speed. After running for 30
minutes, the AC will switch to auto mode with a preset
temperature of 24°C.
Forced auto mode:
Forced auto mode operates the same as normal auto mode
with a preset temperature of 24°C.
The unit exits forced operation when it receives the
following signals:
Switch on
Switch off
Timer on
Timer off
Changes in:
mode
fan speed
setting temperature
3.8 Timer function
Timing range is 24 hours.
Timer on. The machine will turn on automatically
when reaching the setting time.
Timer off. The machine will turn off automatically
when reaching the setting time.
Timer on/off. The machine will turn on
automatically when reaching the setting “on” time,
and then turn off automatically when reaching the
setting “off” time.
Timer off/on. The machine will turn off
automatically when reaching the setting “off” time,
and then turn on automatically when reaching the
setting “on” time.
The timer function will not change the AC current
operation mode. Suppose AC is off now, it will not
start up firstly after setting the “timer off” function.
And when reaching the setting time, the timer LED
will be off and the AC running mode has not been
changed.
The setting time is relative time.
The AC will quit the timer function when it has
malfunction
3.9 Sleep function
The sleep function is available in cooling, heating, or
auto mode.
The operational process for sleep mode is as follows:
When cooling, the temperature rises 1°C (to not
higher than 30°C) every hour. After 2 hours, the
temperature stops rising and the indoor fan is fixed
at low speed.
When heating, the temperature decreases 1°C(to
not lower than 16°C) every hour. After 2 hours, the
temperature stops decreasing and the indoor fan is
fixed at low speed. Anti-cold wind function takes
priority.
The operating time for sleep mode is 8 hours, after
which, the unit exits this mode and does not switches
off.
3.10 Auto-Restart function
The indoor unit has an auto-restart module that

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea MSMABU-09HRDN8-QRD0GW and is the answer not in the manual?

Midea MSMABU-09HRDN8-QRD0GW Specifications

General IconGeneral
BrandMidea
ModelMSMABU-09HRDN8-QRD0GW
CategoryInverter
LanguageEnglish

Related product manuals