22
6.3 Pipe length and the elevation
Capacity
Btu/h
Pipe size Standard
length
(m)
Max.
Elevation
B (m)
Max.
Length
A (m)
Additional
refrigerant
(g/m)
Gas Liquid
MSV1-09HRDN1-QC2
MSV1-12HRDN1-QC2
MSV1-09HRFN1-ND2E
MSV1-09HRDN1-QC8
MSV1-09HRDN1-QC2(D)
4/8’’
(Ф6.35)
3/8’’
(Ф9.53)
5 8 20 20
MSV1-18HRDN1-QC2F(E)
MSV1-18HRDN1-QC2FD
1/2’’
(Ф12.7)
4/8’’
(Ф6.35)
5 10 25 20
MSV1-12HRFN1-ND0E
MSV1-12HRDN1-QC4
MSV1-12HRDN1-QC2(D)
1/2’’
(Ф12.7)
4/8’’
(Ф6.35)
5 8 20 20
MSV1-24HRDN1-QC2W
5/8’’
(Ф16)
3/8’’
(Ф9.53)
5 10 25 40
Caution:
Capacity test is based on standard length and maximum allowance length is based on reliability.
Oil trap should be installed per 5-7 meters.