Conversion to another type of gas
56
Checking the first intake of air
a
Retaining screw
b
Air intake sleeve
Gap X must measure:
For natural gas:13mm
For ULPG gas:13mm
To set gap X
Loosen the retaining screw and
slide the air intake sleeve.
Then screw the retaining screw back
on.
Changing the small jets
a
Small diameter jet
(e.g. for ULPG gas: 0.23)
b
Large diameter jet
(e.g. for ULPG gas: 0.60)
Using a small screwdriver, unscrew
the two small jets and in the gas
fitting.
Pull out the jets with a pair of pliers.
Fit the new jets securely (see jet ta-
ble).
Secure the jets against inadvertent
loosening with sealing wax.