18
Pellerin Milnor Corporation
3.1.1.1 Guards and Related Components
BNUUUH01.R09 0000399322 A.5 A.26 A.9 11/4/21 11:27 AM Released
Examine these items. If an item is damaged, missing, or has the wrong setting, correct this
discrepancy immediately to prevent injury.
Table 1. Guards and Related Components
Mark
Do this each
Component
More Data
1 2
3
4
5
6
x
day* guards, covers Speak to your dealer or Milnor for replacement
components.
x
day* safety placards
x
200 hours fasteners Fasteners must be tight.
x
day* safety stands, bars or pins
(painted red)
Speak to your dealer or Milnor for replacement compo-
nents. See the section “Use the Red Safety Supports for
Maintenance...” in the Safety chapter.
x
200 hours anchor bolts and grout Grout must be good. Bolts must be tight.
x
day* door interlock If the machine operates with the door open:
Immediately remove power.
Do not permit operation.
Speak to your dealer or Milnor.
x
day* emergency stop button
(optional on some washer-
extractors)
See Section 3.2.7 , page 35. Do a test of the control.
x
600 hours mechanical brake See Section 3.3.3 , page 38. Do a test of the mechanical
brake. If it does not operate correctly, repairs are neces-
sary. Speak to your dealer or Milnor. This is not routine
maintenance.
3.1.1.2 Filters, Screens, and Sensitive Components
BNUUUH01.R10 0000399352 A.5 A.26 A.19 11/16/21 10:29 AM Released
Remove contamination from these items to prevent damage and unsatisfactory
performance.
Table 2. Filters, Screens, and Sensitive Components
Mark
Do this each
Component More Data. See also Section 3.1.2 , page 21
1 2 3 4
5
6
x
40 to 60 hours inverter fans, vents, filters See Figure 9, page 29 . Keep good air flow.
x
600 hours
motors
Keep good air flow.
x
2400 hours entire machine Remove excessive dust and dirt.
x
day* chemical inlet areas Some chemical supplies that stay on machine surfaces
will cause corrosion damage. See Section 3.2.3 , page
29 and Section 3.1.2 , page 21. See also, Section 2.3 ,
page 13 for background information.
x
day* self-purging filter (and
regulator) for compressed
air
See Figure 16, page 33. Make sure the bowl drains
automatically.
x
200 hours filter element for the filter
(and reguator)
Replace the filter if you cannot remove contamination.
x
1200 hours mufflers, quick exhaust
valves
See Figure 17, page 34
Routine Maintenance

Table of Contents

Other manuals for Milnor 48040M7K

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Milnor 48040M7K and is the answer not in the manual?

Milnor 48040M7K Specifications

General IconGeneral
BrandMilnor
Model48040M7K
CategoryWasher
LanguageEnglish

Related product manuals