F3 Operations Manual
41
4.8 Changing Sensitivity Endcaps. The F3 can be used
with Black (maximum sensitivity) or Red (minimum sensitivity)
Sensitivity Endcaps. The decision on which Endcap to use will be
provided by the local authority. To exchange a Sensitivity Endcap:
a. Ensure the F3 is switched off.
b. Place the thumb of one hand in the centre of the Endcap and
curl the fingers under the base of the Endcap.
c. Gently push inwards with the thumb and simultaneously pull the
base of the Endcap away from the Electronics Pack (Figure 29).
d. Fit the new Endcap by gently positioning the inside of the base
of the Endcap under the base of the Electronics Pack. Using the
palm of the hand, apply light pressure to fit the Endcap into
position.
Figure 29: Removing a Sensitivity Endcap
P0650-A