Chapter 5 Options
5–14
(3) Detector cable connection
< CNV2 cable connection diagram >
This is an actual connection diagram for the CNV2 cable supplied by Mitsubishi. The connection
differs according to the cable length.
(20m or less) (20 ~ 30m)
< Connection diagram for cable manufacturing >
Manufacture the cable as shown below. The cable can be up to 30m long.
POINT
The CNV2 cable has general-purpose characteristics that allow it to be used with
other detectors.
When manufacturing cable for the HC Motor, only connect the pins that will
actually be used.
CAUTION
1. Do not connect anything to pins unless particularly described when
manufacturing cable. (Leave OPEN.)
2. Contact Mitsubishi before manufacturing cable over 30m long.
H
J
K
L
E
R
S
N
6
16
7
17
9
1
11
19
12
20
PE
SD MD
SD MDR
RQ MR
RQ MRR
BT BAT
5G LG
+5VP5
Plate
Amplifier side Detector side
A
B
C
D
F
G
H
J
K
L
M
U
T
V
E
S
R
N
2
12
3
13
4
14
6
16
7
17
8
18
5
15
9
19
10
20
1
11
PE
SD MD
SD MDR
RQ MR
RQ MRR
BT BAT
+5VP5
5G LG
Plate
Amplifier side Detector side
A
B
C
D
F
G
H
J
K
L
M
U
T
V
E
S
R
N
2
12
3
13
4
14
6
16
7
17
8
18
5
15
9
19
10
20
1
11
PE
SD MD
SD MDR
RQ MR
RQ MRR
BT BAT
+5VP5
5G LG
Plate
Amplifier side Detector side