ON-VEHICLE SERVICE
TSB Revision
INTAKE AND EXHAUST
15-8
TURBOCHARGER WASTE GATE SOLENOID
CHECK
M1151001300272
No.1 turbocharger wastegate solenoid or brown
connector
.
A Operation check
AK703285
AC
No. 1 turbochager
wastegate solenoid valve
AK200441
BATTERY
A
B
AD
1. Install the hand vacuum pump to the nipple "A" of solenoid.
2. Use the jumper wire to connect the solenoid terminal with
the battery terminal.
3. Disconnecting the jumper wire at the negative (-) battery
side, apply the vacuum pressure. Check the airtightness.
Jumper wire Nipple "B" state Normal state
Connected Opened Negative
pressure leaks
Closed Negative
pressure
maintained
Disconnected Opened Negative
pressure
maintained
.
B Check of coil resistance
AK200442
1. Measure the resistance between the solenoid terminals.
Standard value: 29 35 at 20° C