EasyManuals Logo
Home>Mitsubishi>Controller>MELSEC Q Series

Mitsubishi MELSEC Q Series Structured Programming Manual

Mitsubishi MELSEC Q Series
268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #57 background imageLoading...
Page #57 background image
5.1 Type Conversion Functions
5.1.8 Word (signed), double word (signed) type
single-precision real type conversion
5-23
5
APPLICATION
FUNCTIONS
INT_TO_REAL(_E),
DINT_TO_REAL(_E)
INT_TO_REAL(_E), DINT_TO_REAL(_E)
5.1.8 Word (signed), double word (signed) type single-precision
real type conversion
INT_TO_REAL(_E), DINT_TO_REAL(_E)
Function
Operation processing
(1) INT_TO_REAL, INT_TO_REAL_E
Converts word (signed) type data input to into single-precision real type data, and outputs
the operation result from .
INT_TO_REAL(_E)
DINT_TO_REAL(_E)
_E: With EN/ENO
indicates any of the following
functions.
INT_TO_REAL INT_TO_REAL_E
DINT_TO_REAL DINT_TO_REAL_E
Input argument, EN:
Executing condition (TRUE: Execution, FALSE: Stop) :Bit
s:
Input :Word (signed), double word (signed)
Output argument, ENO:
Output status (TRUE: Normal, FALSE: Error) :Bit
d:
Output :Single-precision real
Universal
UD
High
Performance
EN ENO
ds
INT_TO_REAL_E
(EN, s, d);ENO:=
Structured ladder
ST
INT_TO_REAL_E
s
d
Word (signed) type
1234
Single-precision real type
1234.0

Table of Contents

Other manuals for Mitsubishi MELSEC Q Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC Q Series and is the answer not in the manual?

Mitsubishi MELSEC Q Series Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC Q Series
CategoryController
LanguageEnglish

Related product manuals