EasyManuals Logo
Home>Motorola>Radio>CM140

Motorola CM140 Service Manual

Motorola CM140
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #52 background imageLoading...
Page #52 background image
5-2 POWER UP SELF-TEST
2.0 Error Codes (MDC Radios)
Turning on the radio starts a self-test routine that checks the RAM, ROM checksum, EEPROM
hardware, and EEPROM checksum. If these checks are successful, the radio generates two high-
pitched self-test pass tones. If the self-test is not successful, one low-pitched tone is heard. Radios
with displays are able to display the error codes. Following are the possible errors and the related
corrections.
Table 5-2 Power Up Error Codes
Possible Errors To correct the problem...
RAM test failure. Retest the radio by turning it off and turning it on
again. If bad tone reoccurs, replace RAM (U0122).
Codeplug structure mis-
match or non existence of
codeplug.
Reprogram codeplug with correct version and retest
radio. If message reoccurs, replace EEPROM
(U0111).
Wrong codeplug checksum. Reprogram codeplug.

Table of Contents

Other manuals for Motorola CM140

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola CM140 and is the answer not in the manual?

Motorola CM140 Specifications

General IconGeneral
BrandMotorola
ModelCM140
CategoryRadio
LanguageEnglish

Related product manuals