EasyManuals Logo
Home>MSI>Motherboard>MPG Z390I GAMING EDGE AC

MSI MPG Z390I GAMING EDGE AC User Manual

MSI MPG Z390I GAMING EDGE AC
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #69 background imageLoading...
Page #69 background image
69
RAID Configuration
Rebuilding RAID Array
A RAID 1, RAID 5 or RAID 10 volume is reported as Degraded when one of its hard
drive members fails or is temporarily disconnected, and data mirroring is lost. As a
result, the system can only utilize the remaining functional hard drive member. To
re-establish data mirroring and restore data redundancy, refer to the procedure below
that corresponds to the current situation.
1. Power off.
2. Replace the failed hard drive with a new one that is of equal or greater capacity.
3. Reboot the system and go to BIOS > SETTING > Advanced > Intel(R) Rapid Storage
Technology.
4. Select the Degraded RAID volume from the Intel(R) Rapid Storage Technology
screen to enter the RAID VOLUME INFO screen.
5. Select the Rebuild item and press Enter key to rebuild the new hard drive.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MSI MPG Z390I GAMING EDGE AC and is the answer not in the manual?

MSI MPG Z390I GAMING EDGE AC Specifications

General IconGeneral
BrandMSI
ModelMPG Z390I GAMING EDGE AC
CategoryMotherboard
LanguageEnglish

Related product manuals