Chapter 6 NI-VXI Configuration Utility
PCI-MXI-2 for Linux 6-10 ni.com
Resource Manager Delay
The only option under the Resource Manager portion of the Logical
Address Configuration Editor is the Resource Manager Delay control.
Note This field is effective only when the PCI-MXI-2 is at its default logical address of 0.
The PCI-MXI-2 is the Resource Manager only if its logical address is 0.
This field specifies the time in seconds that the Resource Manager (RM)
waits before accessing any other VXI/VMEbus device’s A16 configuration
registers.
Figure 6-5 shows the Device Configuration Editor. The following
paragraphs describe the options you can select for each of the fields.
Figure 6-5. PCI-MXI-2 Device Configuration
RM Delay Range Default Value
0 to 65535 s 5