EasyManuals Logo
Home>National Instruments>Recording Equipment>MXI-2 Series

National Instruments MXI-2 Series User Manual

National Instruments MXI-2 Series
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #81 background imageLoading...
Page #81 background image
Chapter 6 NI-VXI Configuration Utility
© National Instruments Corporation 6-19 PCI-MXI-2 for Linux
Figure 6-8. VXI/VME-MXI-2 Configuration Editor
LA Selection and Logical Address
You can set or modify the logical address of the VXI/VME-MXI-2 either
within the VXI/VME-MXI-2 Configuration Editor itself or with the
onboard 8-position DIP switch. To select the configuration method you
prefer, use the LA Selection controls.
The default selection is the Switch option. Notice that the Logical Address
control is inaccessible, because it would have no effect. In this option you
need to change the hardware switch setting on the VXI/VME-MXI-2 itself
if you want to change the logical address.
If you select Software for this option, you can then use the Logical
Address control to select a logical address within the range of 1 to 254.
If you use this option, the hardware switch setting has no effect and you
must use the VXI/VME-MXI-2 Configuration Editor to change the logical
address.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments MXI-2 Series and is the answer not in the manual?

National Instruments MXI-2 Series Specifications

General IconGeneral
BrandNational Instruments
ModelMXI-2 Series
CategoryRecording Equipment
LanguageEnglish

Related product manuals