2-26 | ni.com
Chapter 2 Basic Functions
Constant voltage control using an Vext or Rext (CF06)
External control setting for turning output on and off (CF09)
Voltage and current setting limits (CF15 and CF14)
CF01 Master-slave Parallel Operation Parameter
Sets the total number of units (master unit and slave units) in master-slave parallel operation.
Specify “SLAV” for the units that you want to use as slaves. This parameter is applied when you
turn the POWER switch off and on.
Changing this setting may affect the settings of the master unit or the slave units that are
connected in parallel.
CF02 Power-on Status Parameter
Sets the condition that the RMX programmable power supply will be in when the power is turned
on. This setting is invalid when you are using an external contact to turn the output off. This
parameter only applies when you turn the POWER switch off and on.
You can only specify this parameter when the RMX programmable power supply is being used
as a master unit.
Value Parameter Description
rSt Resets the panel settings
Value Parameter Description
SLAV Use the RMX as a slave unit
1 to 4 Set the total number of units (1 to 4; 1 indicates independent
operation–factory default setting).
Value Parameter Description
SAFE The settings that were in use immediately before the POWER
switch was turned off are used. The output is off (factory default
setting).
Auto The settings that were in use immediately before the POWER
switch was turned off are used. This includes whether output was
on or off.
ForC The settings that were in use immediately before the POWER
switch was turned off are used. The output is turned on.

Table of Contents

Other manuals for National Instruments RMX-4120

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments RMX-4120 and is the answer not in the manual?

National Instruments RMX-4120 Specifications

General IconGeneral
BrandNational Instruments
ModelRMX-4120
CategoryPower Supply
LanguageEnglish

Related product manuals