3-2 | ni.com
Chapter 3 External Control
Attaching the J1 Cable Core
To connect to the J1 connector, requires a core on the cable for connection. The core is not
included. Use an appropriate core.
1. Unlock the snap-on core and open to split.
Figure 3-2. Unlocking the Snap-on Core
2. Wrap the cable twice around either half of the open core. Wrap the wire so that the distance
between the core and the J1 connector is within 30 mm.
Figure 3-3. Wrapping the Cable Around the Open Core
3. Close the core keeping the J1 cable from being wedged in between. Check that the core is
securely locked.
Figure 3-4. Unlocking the Snap-on Core
Unlock and
open the core
30 mm
To J1 connector
Core
To connection