RMX Programmable Power Supplies User Manual
© National Instruments | 2-43
Note V
OUT
= Output terminal voltage.
Note V
OUT
= Output terminal voltage.
Table 2-6. Sink Current From an External Source when Bleeder is On/Off
Model
Bleeder
Circuit
Sink Current
5 V
OUT
1
10 V
OUT
20 V
OUT
30 V
OUT
40 V
OUT
50 V
OUT
60 V
OUT
70 V
OUT
80 V
OUT
RMX-4121/
RMX-4125
ON 704 mA 667 mA 593 mA 519 mA 444 mA 370 mA 296 mA 222 mA 148 mA
OFF 0.2 mA 0.3 mA 0.5 mA 0.7 mA 0.9 mA 1.1 mA 1.3 mA 1.5 mA 1.7 mA
1
Even when the bleeder is on, the sink current decreases gradually at output terminal voltages lower than this voltage. If the output terminal voltage is near
0 V, hardly any current will be sunk even when the bleeder is on.
Table 2-7. Sink Current From an External Source when Bleeder is On/Off
Model
Bleeder
Circuit
Sink Current
20 V
OUT
1
50 V
OUT
100 V
OUT
200 V
OUT
300 V
OUT
400 V
OUT
500 V
OUT
600 V
OUT
650 V
OUT
RMX-4123/
RMX-4127
ON 463 mA 325 mA 217 mA 130 mA 93 mA 73 mA 59 mA 50 mA 47 mA
OFF 0.2 mA 0.5 mA 0.9 mA 1.7 mA 2.5 mA 3.4 mA 4.2 mA 5.0 mA 5.5 mA
1
Even when the bleeder is on, the sink current decreases gradually at output terminal voltages lower than this voltage. If the output terminal voltage is near
0 V, hardly any current will be sunk even when the bleeder is on.

Table of Contents

Other manuals for National Instruments RMX-4125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments RMX-4125 and is the answer not in the manual?

National Instruments RMX-4125 Specifications

General IconGeneral
BrandNational Instruments
ModelRMX-4125
CategoryPower Supply
LanguageEnglish