2-46 | ni.com
Chapter 2 Basic Functions
CF12
1
Output-on startup state parameter CV (CV is prioritized)
CF13 Detection time of OCP activation 0 ms
CF14
1
Current setting limit ON (the setting is limited)
CF15
1
Voltage setting limit ON (the setting is limited)
CF16 Panel display brightness setting 7
CF17 Communication monitor timer setting OFF (Communication monitoring timer off)
CF18 Unused —
CF19
3
Display setting on slave units for
master-slave parallel operation
OFF (not displayed on slave units)
CF20 LAN interface parameter LAN (the LAN interface will be used)
CF21 Command language parameter SCPI
CF22 Emulation parameter during remote
control
NONE (RMX programmable power supply
commands)
CF23 SCPI communication error display
parameter
OFF (not displayed)
CF24 Multichannel (VMCB) domain number 0 (the multichannel function is not used)
CF25 Multichannel (VMCB) channel number 0 (the RMX programmable power supply is
used as a master unit on the multichannel
network)
CF41 IP address assignment method DHCP: ON
AUTO IP: ON
MANUAL IP: OFF
CF47 SCPI-RAW protocol TCP port number 5025
CF52 RS232C baud rate parameter 19.2 (kbit/s)
1
You can only specify this parameter when the RMX programmable power supply is being used as a master unit.
2
0 to 0.5 V or shorted.
3
You can only specify this parameter when the RMX programmable power supply is being used as a slave unit.
Table 2-10. CONFIG Settings (Continued)
Parameter
Number CONFIG Parameter Parameter Description