UNIVERGE SV8300 Features and Specifications Manual (ISDN/Q-SIG)
Page 2
NWA-033632-001, Issue 1
Advice of Charge - Display
Advice of Charge - Display
General Description
When an outgoing connection is made on the ISDN trunk, this feature provides the call originator with the
charge information form the network. The information will be displayed on the calling Multiline Terminal LCD
for six seconds after the station has been released, and be output to the SMDR/PMS port.
Operating Procedure
No manual operation is required.
Service Conditions
General Conditions
1. Advice of Charge (AOC) service is supported based on the following specifications.
ISDN AOC-E, which is based on the AOC supplementary service for ISDN (ETS 300 182, August
1993).
•Display AOC-E, which uses the ISDN Display Information Element, as defined in ITU-T Q.931 to con-
vey textual AOC information.
•CEPT AOC-E, which uses the CEPT Charge Advice Information Element.
2. This feature supports only Advice of Charge at the end of the call (AOC-E). If Advice of Charge during the
call (AOC-D) information is sent, the information is ignored.
3. The 2BRI or the PRI blade is required.
4. Charge information control for each country is specified by the ISDN protocol type setting in system data
programming.
5. The CPU calculates the call charge according to the UT (charging unit) sent from the AP (BRT/PRT).
Call charge=UT x Unit rate
UT (charging unit): UT sent from AP
Unit rate: Rate specified by system data programming
6. The unit rate can be set to two places of decimals. When the unit rate has three or more decimal places, it is
required to round up or truncate the number to two decimal places and set that value. The integral part of
unit rate can be set to maximum two digits.
7. If AOC information is not sent due to the cause of network, call charge information is not displayed.
8. The call charge information is displayed on a Multiline Terminal in the following range.
0.01 - 655.35
Note:
“655.35” is the maximum value, which the CPU can calculate.