9ES
GB
3 kW 6 kW
OFF
H
70
100
*
30 – 65
20 – 55
*
Ø D
90
9
8
11
14
5
95
170
200
*
42
41
C
47
B A
V. v.
K.v.
10*
D
approx. 60 °C
H
70
100
*
30 – 65
20 – 55
*
Ø D
90
9
8
11
14
5
95
170
200
*
42
41
C
47
B A
V. v.
K.v.
10*
D
Electrical installation
The water heater shall be installed via an isolator switch.
The connecting wire is connected to the terminal block
(4) in the connector housing (9) in accordance with
markings on the terminal block, and clamp the wires
in the strain relief clamp, cf. also wiring diagram in the
connector housing.
Single phase installation will only give an output of
1.0 kW.
Circuit diagram 1 kW / 3 kW
Standard for ES 160/210.
Circuit diagram 6 kW
Standard for ES 300/500 and alternative design for ES
160/210.
4 4
5
6
400 V~
2-fas 3kW
230 V~
1-fas 1kW
33
2
1
L2
L1
PE
L1
N
PE
A
B
4
5
6
Läge 3 kW Läge 6 kW
14
400 V~
3-fas
12
22
32
11
21
31
P3
P1
P2
5
2
4
P3
P1
P2
5
2
4
P3
P1
P2
5
2
4
L3
L2
L1
PE
ES 160/210/300 ES 500 samt alternativutf. för ES 160/210/300
400 V~
2-phase
3kW
230 V~
1-phase
1kW
4 4
5
6
400 V~
2-fas 3kW
230 V~
1-fas 1kW
33
2
1
L2
L1
PE
L1
N
PE
A
B
4
5
6
Läge 3 kW Läge 6 kW
14
400 V~
3-fas
12
22
32
11
21
31
P3
P1
P2
5
2
4
P3
P1
P2
5
2
4
P3
P1
P2
5
2
4
L3
L2
L1
PE
ES 160/210/300 ES 500 samt alternativutf. för ES 160/210/300
400 V~
3-phase
3kW Position 6kW position
LEK
Adjustment of the thermostat
A setting of 60 °C (max about 80 °C) is recommended
for the best operating conditions.
Electrical installation and service must be
carried out under the supervision of a
qualified electrician.
NOTE!
The water heater must be filled with water
before the power is switched on.
NOTE!
Output selector (6 kW)
Set the output selector of the water heater to the
output required. As the immersion heater has lowest
output at 3 kW this position should be used normally.
When greater output is required, for example when
night rates apply, put the output selector in the 6 kW
position.
Immersion heater 6 kW
Electrical installation

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe ES Series and is the answer not in the manual?

Nibe ES Series Specifications

General IconGeneral
Protection ClassIP21
SeriesES
TypeElectric
Voltage230/400 V
ControlElectronic
CategoryElectric Boiler
WeightVaries by model (approximately 25-40 kg)