14
Pause Time
Step-by-step
Function
Obstacle
detection
sensitivity
Open gate
indicator
output
Motor force
control
L1
L2
L3
L4
L5
L6
L7
L8
L1
L2
L3
L4
L5
L6
L7
L8
L1
L2
L3
L4
L5
L6
L7
L8
L1
L2
L3
L4
L5
L6
L7
L8
L1
L2
L3
L4
L5
L6
L7
L8
5 Seconds
15 Seconds
30 Seconds
45 Seconds
60 Seconds
80 Seconds
120 Seconds
180 Seconds
Open - stop - close - stop
Open - stop - close - open
Open - close - open - close
Apartment block
Apartment block (more than 2” generates stop)
Step-by-step 2 (less than 2” generates partial open)
Dead man
Opening in semi-automatic mode, closing in
dead man mode
Very high sensitivity (lightweight gates)
Very high sensitivity
High sensitivity
Medium sensitivity
Medium-low sensitivity
Low sensitivity
Very low sensitivity
Very low sensitivity (heavyweight gates)
Gate Open Indicator function
Active if leaf closed
Active if leaf open
Active with radio output 2
Active with radio output 3
Active with radio output 4
Maintenance indicator
Electric lock
Set at 40%
Set at 50%
Set at 60%
Set at 80%
Set at 100%
Semiautomatic 1=40÷100% (1)
Semiautomatic 2=60÷100% (1)
Automatic = 0÷100% (2)
7.2.2) Level one programming (ON-OFF functions)
Level 1 functions are all factory set to “OFF”. However, they can be changed at any time as shown in Table 8. Follow the procedure careful-
ly, as there is a maximum time of 10 seconds between pressing one key and another. If a longer period of time lapses, the procedure will fin-
ish automatically and memorize the modifications made up to that stage.
1. Press and hold key [Set] (approx. 3 s)
3s
2. Release the [Set] key when L1 LED starts flashing
L1
3. Press keys [▲] or [▼] to move the flashing LED onto the LED representing the function to be changed
o
4. Press the [Set] key to change the state of the function (short flashing = OFF; long flashing = ON)
5. Wait 10 seconds before leaving the programme to allow the maximum time to lapse.
10s
Note: Points 3 and 4 can be repeated during the same programming phases in order to set other functions to ON or OFF
Table 8: changing ON-OFF functions Example
7.2.3) Level two functions (adjustable parameters)
Table 9: programmable function list: level two
Input LED Parameter Led (level) Value Description
Adjusts the pause time, i.e. the time which
lapses before automatic closure. This will
only have an effect if automatic closing is
active.
Manages the sequence of controls associ-
ated with the Step-by-Step input or to the
1st radio command.
Controls obstacle detection sensitivity. Take
care that sensitivity is also influenced by the
force of the motor (see L5); the motor force
should always be adjusted beforehand, to
enable correct settings of obstacle detec-
tion sensitivity.
Adjust the function associated with the open
gate indicator output (regardless of the
associated function, when active, it supplies
a voltage of 24V -30 +50% with maximum
power of 4W).
After start-up of the motor, set the force to
adapt it to the weight of the gate. The con-
trol system also measures the ambient tem-
perature, increasing force automatically in
the event of particularly low temperatures.
L1
L2
L3
L4
L5