This PAGE is only for the inverter model
" Run 2500 Inverter "
(GB) CAUTION:
The product has undergone an update: in the version Run 2500 I, replace the corresponding parts of the manual
enclosed with the product, with the following updated sections:
2) Product description and applications
RUN 2500 I is powered by a common single phase 230V electric power line. It is equipped with a powerful and efficient 3-phase motor
controlled by a special “inverter” control unit, which enables adjustment of speed.
7.2.1) Level one functions (ON-OFF functions)
Table 7: programmable function list: level one
LED Function Description
L4 Deceleration
On activation of this function, a deceleration phase is activated at the end of the opening or closing
manoeuvre. The final deceleration speed corresponds to approx. 0.05 m/s, regardless of the speed set
during the manoeuvre. If deceleration is not active the speed remains constant throughout the manoeuvre.
Caution: Run 2500 I maintains the same force applied during the manoeuvre also during deceleration;
therefore deceleration can also be implemented on very heavyweight gates.
7.2.3) Level two functions (adjustable parameters)
Table 9: programmable function list: level two
Input LED Parameter LED (level) Value Description
L1
Speed 0,06m/s
L2
Speed 0,09m/s
L3
Speed 0,13m/s
L4
Speed 0,17m/s
L5
Speed 0,20m/s
L6
Speed 0,25m/s
L7
Speed 0,17m/s in opening; 0,09m/s in closing
L3
Motor
speed
L8
Speed 0,25m/s in opening; 0,17m/s in closing
Adjusts motor speed during normal travel.
L1
Extremely high sensitivity (lightweight gates)
L2
Very high sensitivity
L3
High sensitivity
L4
Medium sensitivity
L5
Medium-low sensitivity
L6
Low sensitivity
L7
Very low sensitivity (heavyweight gates)
L5
Obstacle
detection
sensitivity
L8
Detention excluding (for gates with jolts)
Adjusts the sensitivity of obstacle
detection.
8) Technical characteristics
Run 2500 I Technical characteristics
Product Type
Electromechanical gearmotor with three-phase motor for automatic movement of sliding
gates for industrial use complete with electronic control unit and inverter.
Maximum torque on start-up
(corresponds to the force required to move the leaf)
60Nm
(1660N)
Nominal torque
(corresponds to the force required to maintain the leaf in
movement)
25Nm
(700N)
No-load speed
0.17m/s with speed = L4; the speed is adjustable from 0.06 to 0.25m/s
Speed at nominal torque
0,15m/s with speed = L4
Maximum frequency of operating cycles
(at nominal torque)
28 cycles/hour (672 cycles/day), for a gate of 10m; equal to a cycle of 93%. The control
unit limits the cycles to the maximum limits as specified in tables 2 and 3)
**
Maximum time of continuous operation
(at nominal torque)
45 minutes. The control unit limits continuous operation to the maximum limits as specified
in tables 2 and 3)***
Run 2500 I Power supply
230Vac (+10% -15%) 50/60Hz
Maximum power absorption on start-up [corresponding
to Amps]
650W [3.7 A]
Power at nominal torque
[corresponding to Amps]
450W [2.6 A]
Note ** at 50°C and with a gate of 17.5 m the maximum operating frequency is 6 cycles/hour (equal to a cycle of 35%).
Note *** at 50°C the maximum continuous operating time is 20 minutes.

Table of Contents

Other manuals for Nice RUN2500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nice RUN2500 and is the answer not in the manual?

Nice RUN2500 Specifications

General IconGeneral
BrandNice
ModelRUN2500
CategoryGate Opener