Pump
B 2-12
E 2000 Nordson Corporation
All rights reserved
41-3000
Issued 11/00
B2EN-02-[3-PUMP]-5
Follow this procedure to disassemble the pump .
1. See Figure B 2-2. Remove the bolts that secure the pump to the
pump mount (1). Be careful not to lose the drive shaft coupling (4)
and key (3).
2. Remove the return tube (7) and the crossover tube (5).
3. Check the crossover tube O-ring (6) for damage. Replace the O-ring
if necessary.
NOTE: Nordson Corporation recommends replacing the crossover
tube O-ring any time the pump is removed.
4130903A
3
4
6
7
1
5
2
Fig. B 2-2 Return Tube and Crossover Tube Components
1. Pump mount
2. Key
3. Pump mount insulator
4. Coupling
5. Crossover tube
6. Crossover tube O-ring
7. Return tube
Disassembling the Pump