Pump
B 2-13
E 2000 Nordson Corporation
All rights reserved
41-3000
Issued 11/00
B2EN-02-[3-PUMP]-5
WARNING: Risk of burns. Solidified adhesive may make the
pump plates difficult to separate. If you need to heat the pump
plates, use an electric oven with forced-air circulation or a
flameless electric heat gun. Do not use a torch or other open
flame.
4. Disassemble the pump as shown in Figure B 2-3. Be careful not to
lose the steel balls (2).
4130904A
1
2
3
4
6
7
8
5
9
Fig. B 2-3 Pump Components
1. Drive shaft
2. Steel ball (one of two)
3. Bottom plate
4. Center plate
5. Spur gears
6. Idler shaft
7. Top plate
8. Socket-head screw (one of four)
9. Dowel pins