6. Appendix
Appendix A. Instructions converted by Change Model on CX-Programmer
(1) The data type of operand is changed from BCD data to BIN data for some instructions.
(2) The number of operand is changed for some instructions.
(3) Interrupt control instructions must be changed. (Use MSKS, MSKR, CLI, DI, and EI).
Refer to the list below for detail. The table lists the instructions which are automatically converted producing some difference
between instructions before and after conversion. The other instructions are automatically converted.
Instruction for
C200H
Instruction for CS1 Operand Number of Operand
JMP(04)
JMP(4) or
JMP0(515)
When #0 is set to the Operands, JMP is converted
to JMP0 and operand is deleted.
If #0 is not set, same as C200H.
#0: 1 -> 0
= #0: Same
JME(05) JME(5) or
JME0(516)
When #0 is set to the Operands, JME is converted
to JME0 and operand is deleted.
If #0 is not set, same as C200H.
#0: 1 -> 0
= #0: Same
WSFT(16) Same as C200H #0 is added to the Operand1.
WSFT D1 D2 -> WSFT #0 D1 D2
Changed from 2 to 3
FUN17
ASFT(017)
Same as C200H Same
XFER(70)
XFERC(565)
Same as C200H Same
MOVB(82)
MOVBC(568)
Same as C200H Same
DIST(80)
DISTC(566)
Same as C200H Same
COLL(81)
COLLC(567)
Same as C200H Same
FUN60
CMPL(060)
Same as C200H Same
FUN19
MCMP(019)
Same as C200H Same
FUN63
LINE(063) Changed from BCD data to BIN data.
Same
FUN64
COLM(064) Changed from BCD data to BIN data.
Same
FUN65
SEC(065)
Same as C200H Same
FUN66
HMS(066)
Same as C200H Same
INC(38)
++B(594)
Same as C200H Same
DEC(39)
--B(596)
Same as C200H Same
ADD(30)
+B(404)
Same as C200H Same
ADDL(54)
+BL(405)
Same as C200H Same
SUB(31)
-B(414)
Same as C200H Same
SUBL(55)
-BL(415)
Same as C200H Same
MUL(32)
*B(424)
Same as C200H Same
MULL(56)
*BL(425)
Same as C200H Same
DIV(33)
/B(434)
Same as C200H Same
DIVL(57)
/BL(435)
Same as C200H Same
ADB(50)
+(400)
Same as C200H Same
SBB(51)
-(410)
Same as C200H Same
MLB(52)
*(420)
Same as C200H Same
DVB(53)
/(430)
Same as C200H Same
FUN69
APR(069)
Same as C200H Same
FUN89 Not supported
Combine and use below instructions: MSKS(690), CLI(691), MSKR(692), DI(693),
EI(694)
STEP(08) Same as C200H
The CIO, Holding, Work, Auxiliary, DM, and EM Area
are all converted into the WR relay.
Same
SNXT(09) Same as C200H
Use a differentiated
execution condition
for the SNXT
instruction.
Same as C200H Same
FAL(06) Same as C200H #0 is added to Operand 2.
FAL N -> FAL N #0
Changed from 1 to 2.
FALS(07) Same as C200H #0 is added to Operand 2.
FALS N -> FALS N #0
Changed from 1 to 2.
MSG(46)
MSG(46)
#0 is added to Operand 1.
MSG S -> MSG #0 S
Number of characters (words) to be registered from first
message word (S) is changed from 16 characters (8
words) to 32 characters (16 words).
Changed from 1 to 2.
FUN47
Not supported
Use MSG(46), instead.
FUN67
BCNTC(621)
Same as C200H Same
WDT(94)
WDT(094) Control data configuration is different.
Same
FUN61
IORF(097)
On CS1, Unit No, of C200H Group-2 High-density I/O Units is disabled. Specify the
allocation by using IORF in the same way as Basic I/O Units.
FUN18
Enter the settings from PLC settings.
FUN48
Not supported
FUN49
Enter the settings from PLC settings.
FUN90
SEND(090) Control data configuration is different.
Same
FUN98
RECV(098) Control data configuration is different.
Same
󲨩󲨫