E8F2 E8F2
9
J MODES
In addition to displaying measurement val ues, the E8F2 has a variety of functions. These functions are avai labl e i n four main modes as
described below: Measurement Mode, Basi c Setting Mode, Pressure Setti ng Mode, Special Setting Mode. Three functions are available
in measurement mode. F or the relationships among each mode and for sw itching methods, refer to the foll owi ng figure.
Power ON
Zero-reset function
ON- and OFF-point
check function
No key operation
No key operation
Measurement
Mode
Energy-saving function 1
Energy-saving function 2
or
or
Basic Setting Mode
unt: Measurement unit selection
m-a: Pressure settin g method
selectio n
ope: Output-type selection
Pressure Setting Mode
on: OUT1 ON-point setting
off: OUT1 OFF-point setting
Manual setting
on: OUT2 ON-point setting
off: OUT2 OFF-point setting
t.h1: OUT1 two-point teaching
t.w: OUT1 one-point teaching
Auto-teaching setting
t.h1: OUT2 two-point teaching
t.w: OUT2 one-point teaching
prt: Key-protect setting
Special Setting Mode
hys: Hysteresis width setting
wid: Window width setting
dsp: Measurement value display
refresh interval setting
aUe: Number of measurement times
s etting for measurement value averaging
bar: LED bar indicator range setting
or
or
Note: 1. and indicate that the key must be pressed for approximately 2 or 3 s respectively.
2. The following will result when the E8F2 in basic, pressure setting, or special setting mode is reset to measurement mode.
: T he set values are entered.
: The set val ues are not entered (left as they are).
*1.Manual setting is avail able by selecting m (manual) in the pressure setting method sel ection in basic setting mode.
*2.Auto-teaching setting is available by selecting a (auto-teaching) i n the pressure setting method selection in basic setting mode.