H3CR-A
H3CR-A
18
Ratings
Rated supply voltage 100 to 240 VAC (50/60 Hz), 12 VDC, 24 VDC/VAC (50/60 Hz), 48 to 125 VDC
Operating voltage range 85% to 110% of rated supply voltage (90% to 110% at 12 VDC)
Power reset Minimum power-opening time: 0.1 s
No-voltage input ON impedance: 1 k
$
max.
ON residual voltage:1 V max.
OFF impedance: 100 k
$
min.
Power consumption 100 to 240 VAC: approx. 10 VA; 12 VDC, 48 to 125 VDC: approx. 1.5 W;
24 VDC/VAC: approx. 2 VA (AC), approx. 1 W (DC)
Control outputs Time limit contacts: 5 A at 250 VAC, resistance load (cos
%
=1)
Transistor output: Open collector (NPN/PNP), 100 mA max. at 30 VDC max.,
residual voltage: 2 V max.
Instantaneous contact: 5 A at 250 VAC, resistance load (cos
%
=1)
Characteristics
Accuracy of operating time
!
0.3% FS max. (
!
0.3%
!
10 ms in a range of 1.2 s)
Setting error
!
5% FS
!
0.05 s max.
Reset time Min. power-opening time: 0.1 s max.
Min. pulse width: 0.05 s (H3CR-A/-AS)
Influence of voltage
!
0.5% FS max. (
!
0.5%
!
10 ms in a range of 1.2 s)
Influence of temperature
!
2% FS max. (
!
2%
!
10 ms in a range of 1.2 s)
Insulation resistance 100 M
$
min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed
non-current-carrying metal parts)
2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit)
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)
Impulse withstand voltage 3 kV (between power terminals) for 100 to 240 VAC, 48 to 125 VDC, 1 kV for 12 VDC,
24 VDC/VAC
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for
100 to 240 VAC, 48 to 125 VDC, 1.5 kV for 12 VDC, 24 VDC/VAC
Noise immunity
!
1.5 kV (between power terminals) and
!
600 V (between input terminals), square-wave noise
by noise simulator (pulse width: 100 ns/1
&
s, 1-ns rise)
Static immunity Malfunction:8 kV
Destruction:15 kV
Vibration resistance Destruction:10 to 55 Hz with 0.75-mm double amplitude each in three directions
Malfunction:10 to 55 Hz with 0.5-mm double amplitude each in three directions
Shock resistance Destruction: 980 m/s
2
(100G) each in three directions
Malfunction:98 m/s
2
(10G) each in three directions
Ambient temperature Operating:--10
"
Cto55
"
C (with no icing)
Storage: --25
"
Cto65
"
C (with no icing)
Ambient humidity Operating: 35% to 85%
Life expectancy Mechanical:20 million operations min. (under no load at 1,800 operations/h)
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h)
Case color Light Gray (Munsell 5Y7/1)
Enclosure ratings IEC: IP40
Weight Approx. 90 g; approx. 110 g (H3CR-A8EL/-A8E)