H3CR-F
H3CR-F
38
Accessories (Order Separately)
Name/specifications Models
Flush Mounting Adapter
Y92F-30
Y92F-73
Y92F-74
Mounting Track 50 cm (
l
)x7.3mm(t) PFP-50N
1m(
l
) x 7.3 mm (t) PFP-100N
1m(
l
)x16mm(t) PFP-100N2
End Plate PFP-M
Spacer PFP-S
Protective Cover Y92A-48B
Track Mounting/
8-pin P2CF-08
Front Connecting Socket
11-pin P2CF-11
Back Connecting Socket
8-pin P3G-08
11-pin P3GA-11
Hold-down Clip For PL08 and PL11 Sockets Y92H-7
For PF085A Socket Y92H-8
Specifications
General
Item H3CR-F H3CR-F8 H3CR-FN H3CR-F8N
Operating mode Flicker OFF start Flicker ON start
Pin type 11-pin 8-pin 11-pin 8-pin
Operating/Reset method Time-limit operation/Time-limit reset or self-reset
Output type Relay output (DPDT)
Mounting method DIN track mounting, surface mounting, and flush mounting
EMC Emission Enclosure: EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
Immunity ESD: IEC801-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference: ENV50140: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Conducted Disturbance: ENV50141: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst: IEC801-4: 2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
Approved standards UL508, CSA C22.2 No.14, LR/NK
Conforms to VDE0435/2021, VDE0110
Conforms to EN50081-2, prEN50082-2
Time Ranges
0.05sto30hModels
Time unit
s (sec) x10 s (10 s) min h(hrs)
Setting 1.2 0.05 to 1.2 1.2to12 0.12 to 1.2
3 0.3to3 3to30 0.3to3
12 1.2to12 12 to 120 1.2to12
30 3to30 30 to 300 3to30
Note: Instantaneous output is available at any time range. To obtain instantaneous output, set to below 0.
1.2 s to 300 h Models
Time unit
x10 s (10 s) x10 min (10 min) h(hrs) x10 h (10 h)
Setting 1.2 1.2to12 1.2to12 0.12 to 1.2 1.2to12
3 3to30 3to30 0.3to3 3to30
12 12 to 120 12 to 120 1.2to12 12 to 120
30 30 to 300 30 to 300 3to30 30 to 300
Note: Instantaneous output is available at any time range. To obtain instantaneous output, set to below 0.