EasyManuals Logo
Home>Omron>Timer>H5CN

Omron H5CN User Manual

Omron H5CN
326 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
H3CR-F
H3CR-F
39
Ratings
Rated supply voltage (see note) 100 to 240 VAC (50/60 Hz),12 VDC, 24 VAC/DC (50/60 Hz), 48 to 125 VDC
Operating voltage range 85% to 110% of rated supply voltage; 90% to 110% with 12-VDC models
Power reset Minimum power-opening time: 0.1 s
Power consumption 100 to 240 VAC: approx. 10 VA; 12 VDC: approx. 1 W;
24 VAC/DC: approx. 2 VA (AC), approx. 1 W (DC); 48 to 125 VDC: approx. 1.5 W
Control outputs Contact output: 5 A at 250 VAC, resistive load (cos
%
=1)
Note: A power supply with a ripple of 20% max. (single-phase power supply with full-wave rectification) can be used with each DC Model.
Characteristics
Accuracy of operating time
!
0.3% FS max. (
!
0.3% FS
!
10 ms in ranges of 1.2 and 3 s)
Setting error
!
5% FS
!
0.05 s max.
Reset time 0.1 s max.
Influence of voltage
!
0.5% FS max. (
!
0.5% FS
!
10 ms in ranges of 1.2 and 3 s)
Influence of temperature
!
2% FS max. (
!
2% FS
!
10 ms in ranges of 1.2 and 3s)
Insulation resistance 100 M
$
min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed
non-current-carrying metal parts)
2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit)
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)
Impulse withstand voltage 3 kV (between power terminals) for 100 to 240 VAC, 48 to 125 VDC
1 kV for 12 VDC, 24 VAC/DC
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts)
for 100 to 240 VAC, 48 to 125 VDC
1.5 kV for 12 VDC, 24 VAC/DC
Noise immunity
!
1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width:
100 ns/1
&
s, 1-ns rise)
!
400 V for 12 VDC
Static immunity Malfunction:8 kV
Destruction:15 kV
Vibration resistance Destruction:10 to 55 Hz with 0.75-mm single amplitude each in three directions
Malfunction:10 to 55 Hz with 0.5-mm single amplitude each in three directions
Shock resistance Destruction: 980 m/s
2
(100G) each in three directions
Malfunction:98 m/s
2
(10G) each in three directions
Ambient temperature Operating:--10
"
Cto55
"
C (with no icing)
Storage: --25
"
Cto65
"
C (with no icing)
Ambient humidity Operating: 35% to 85%
Life expectancy Mechanical:20 million operations min. (under no load at 1,800 operations/h)
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h)
Case color Light Gray (Munsell 5Y7/1)
Enclosure ratings IEC: IP40
Weight Approx. 100 g
Engineering Data
Reference: A maximum current of 0.15 A can be switched at 125 VDC (cos
%
=1)
and a maximum current of 0.1 A can be switched if L/R is 7 ms. In
both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC (failure level: P).
Load current (A)
30 VDC L/R = 7 ms
250VAC/30VDC
(cos
%
=1)
250 VAC (cos
%
=0.4)
Switching operations (x 10 )
3
10,000
5,000
1,000