EasyManuals Logo
Home>Osburn>Indoor Fireplace>INSPIRE 2000

Osburn INSPIRE 2000 User Manual

Osburn INSPIRE 2000
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #35 background imageLoading...
Page #35 background image
Page 35
Installation and Operation Manual - Inspire 2000
9.2.2 Masonry Flue System
The wood fire may also be connected to a masonry
flue system, provided the flue system complies with
AS/NZS 2918 or with the construction rules found in
the building code enforced locally. The flue system
must have either a clay liner or a suitably listed
stainless steel liner. If the masonry flue system has
a square or rectangular liner that is larger in cross
sectional area than a round 150 mm (6») flue, it
should be relined with a suitably listed 150 mm (6»)
stainless steel liner. Do not downsize the flue to less
than 150 mm (6») unless the flue system is straight
and exceeds 8 m (25 feet) in height. When passing
through a combustible wall, the use of an insulated
listed thimble is required.
9.3 Minimum Flue Height

Other manuals for Osburn INSPIRE 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Osburn INSPIRE 2000 and is the answer not in the manual?

Osburn INSPIRE 2000 Specifications

General IconGeneral
BrandOsburn
ModelINSPIRE 2000
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals