26
Outdoor unit
Select a location where the noise and outflow air emitted by the outdoor unit will not affect
neighborhood.
The location should be well ventilated and dry, where the outdoor unit won’t be exposed directly
to sunlight or strong wind.
The location should be able to withstand the weight of outdoor unit.
Make sure that the installation follows the requirement of clearance distance diagram.
Select a location which is out of reach for children and far away from animals or plants. If it is
unavoidable, please add a fence for safety purpose.
Do not install the outdoor unit opposite to an air outlet. Eg.: dryer outlet, kitchen hood, etc.
REQUIREMENTS FOR ELECTRICAL CONNECTION
Safety precautions
Must follow the electric safety regulations when installing the unit.
According to the local safety regulations, use qualified power supply circuit and circuit break.
Make sure the power supply matches with the requirement of the device. Unstable power supply
or incorrect wiring may cause malfunction and damage the unit or fire hazard.
Properly connect the live wire, neutral wire and grounding wire.
Cut off the power supply before proceeding any work related to electricity.
Do not put through the power before finishing installation.
The temperature of refrigerant circuit will be high, please keep the interconnection cable away
from the copper tube.
The appliance shall be installed in accordance with national wiring regulations.
Grounding requirements
The heat pump is a first class electric appliance. It must be properly grounded by a qualified person
with specialized grounding device. Please make sure it is always grounded effectively, otherwise
it may cause electric shock.
The yellow-green wire in the appliance is the grounding wire, which cannot be used for other
purposes.
The grounding resistance should comply with national electric safety regulations.
An all-pole disconnect switch having a contact separation of at least 3mm in all poles should be
connected in fixed wiring.