3Features
3.1. Outdoor Unit
3.1.1. Flexible installation in smaller
spaces
Spacing-saving outdoor unit with the improvement of the
outdoor unit fan makes it possible to install the outdoor unit
into a smaller space where the conventional model cannot
be installed.
Long pipe design with maximum piping lenght of 30m (For
YL24H & YL28H) and 50m (For YL34H & YL43H).
Additional charging of refrigerant are not required for 30m of
pipe length.
Flexible 4-way piping (For YL34H & YL43H only).
Centralized drain method gather multiple outdoor unit’s
drain pipes into a single drain pipe to makes installation
easier and also improve appearance.
Side-by-side continuous Installation is possible even for
outdoor units with different capacities.
3.1.2. Quiet, efficient design
A host of silencing technologies achieves super-quiet
operation.
The noise-suppressing winglet fan is a result of new
research into vane design theory. The unique curved shape
suppresses the generation of vortexes, thus reduces air
flows noise.
Operating efficiency is improved and energy consumption is
reduced.
3.1.3. Low ambient cooling operation
This unit is still able to operate as a cooler with outdoor
temperature as low as -5°C in a non-living room, such as a
computer room, with a room temperature of 21°C or above,
and room humidity up to 45%.

Other manuals for Panasonic CS-F18DB4E5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-F18DB4E5 and is the answer not in the manual?

Panasonic CS-F18DB4E5 Specifications

General IconGeneral
BrandPanasonic
ModelCS-F18DB4E5
CategoryAir Conditioner
LanguageEnglish

Related product manuals