80
11.2.2. Heating performance
1. Heating capacity when the unit is frosted over or while being defrosted will vary depending on outdoor temperature and the
frosting.
2. Heating capacity must be compensated because it does not take into account the capacity drop incurred when the unit is
frosted over and while it is being defrosted.
3. Therefore, to obtain the integral heating capacity in consideration overfrosting and defrost operations.
4. Heating capacity must be multiplied by the compensation coefficient below.
Model name Max heating capacity
Max capacity (kw) Max power consumption (kw)
CS-F14DB4E5 x 2 / CU-YL28HBE5 8.3 3.2
CS-F18DB4E5 x 2 / CU-YL34HBE5 13 4.1
CS-F24DB4E5 x 2 / CU-YL43HBE5 15 4.9
CS-F24DB4E5 / CU-YL24HBE5 7.6 2.8
CS-F28DB4E5 / CU-YL28HBE5 8.3 3.2
CS-F34DB4E5 / CU-YL34HBE5 13 4.1
CS-F43DB4E5 / CU-YL43HBE5 15 4.9